For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
Ethyl 1-(tert-butoxycarbonyl)-4-piperidinecarboxylate
SpectraBase Compound ID 8Wsfs7VDroB
InChI InChI=1S/C13H23NO4/c1-5-17-11(15)10-6-8-14(9-7-10)12(16)18-13(2,3)4/h10H,5-9H2,1-4H3
InChIKey MYHJCTUTPIKNAT-UHFFFAOYSA-N
Mol Weight 257.33 g/mol
Molecular Formula C13H23NO4
Exact Mass 257.162708 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID xGz5nPXRGw
Name Ethyl 1-(tert-butoxycarbonyl)-4-piperidinecarboxylate
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number B2740
Lot Number UQ7CH-MM
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 16
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270664
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1625
Backward Peak Location 7352
Beam Splitter Setting KBr
CAS Registry Number 142851-03-4
Color Properties Colorless
Container ID C-010149
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C13H23NO4
Frequency of First Point 3998.29 cm⁻¹
Frequency of Last Point 339.459 cm⁻¹
High Folding Limit 15800.3
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C13H23NO4/c1-5-17-11(15)10-6-8-14(9-7-10)12(16)18-13(2,3)4/h10H,5-9H2,1-4H3
InChIKey MYHJCTUTPIKNAT-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.3 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1656
Peak Amplitude 2nd Channel 1
Peak Location 7383
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Liquid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity >97.0%
Relative Humidity Interferometer 10 %
Resolution 4
SKU B2740-5G
SMILES C1CN(CCC1C(OCC)=O)C(OC(C)(C)C)=O
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.306 s
Scanner Temperature 29.6 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms Piperidine-1,4-dicarboxylic acid 1-tert-butyl 4-ethyl ester
Technique ATR-Neat
Zero Filling Factor 4