SpectraBase Spectrum ID |
pIjRmnb3mT |
Name |
L-Glutamic acid di-tert-butyl ester hydrochloride |
Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
Catalog Number |
H63708 |
Lot Number |
Z21C044 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
1 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
1 |
Analog Signal 1 |
0.222536 |
Analog Signal 2 |
0 |
Aperture Setting |
2.5 mm |
Apodization Function |
Norton-Beer, medium |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Backward Peak Amplitude |
2042 |
Backward Peak Location |
28691 |
Beam Splitter Setting |
Quartz |
CAS Registry Number |
32677-01-3 |
Calibration Lamp Spectrum |
Correction.0 |
Color Properties |
White |
Container ID |
C-009803 |
Copyright |
Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
15 s |
Detector Setting |
LN-Ge Diode [Internal Pos.2] |
End Frequency Limit for File |
9394.3 |
External Analog Signals |
Off |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C13H26ClNO4 |
Frequency of First Point |
3597.79 cm⁻¹ |
Frequency of Last Point |
-1.31092 cm⁻¹ |
High Folding Limit |
31596.8 |
High Frequency Limit |
30000 cm⁻¹ |
High Pass Filter |
1 |
InChI |
InChI=1S/C13H25NO4.ClH/c1-12(2,3)17-10(15)8-7-9(14)11(16)18-13(4,5)6;/h9H,7-8,14H2,1-6H3;1H/t9-;/m0./s1 |
InChIKey |
LFEYMWCCUAOUKZ-FVGYRXGTSA-N |
Instrument Name |
Bruker MultiRAM Stand Alone FT-Raman Spectrometer |
Laser Wavenumber |
15798.4 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
5 |
Measurement Channel |
Raman Compartment |
Non Linearity Correction |
0 |
Number of Points |
7466 |
Number of Sample Scans |
64 |
Optical Filter Setting |
Open |
Peak Amplitude |
1998 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
28693 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
power spectrum |
Phase Resolution |
1 |
Physical State |
Liquid |
Preamplifier Gain |
0 |
Purity |
98% |
Raman Background Corrected |
Yes |
Raman Corrections |
Referenced to internal light source; Scattering corrected |
Raman Laser Source |
Nd:YAG |
Raman Scattering Corrected |
Yes |
Relative Humidity Interferometer |
30 % |
Resolution |
2 |
SKU |
H63708-1G |
SMILES |
Cl.N[C@@](CCC(OC(C)(C)C)=O)(C(OC(C)(C)C)=O)[H] |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
2 |
Scan Time |
790.313 s |
Scanner Temperature |
26.9 °C |
Scanner Velocity |
5 kHz |
Signal Gain, Sample |
2 |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
5794.76 cm⁻¹ |
Start Time |
1.53184e+09 s |
Synonyms |
L-Glutamic acid bis-tert-butyl ester hydrochloride |
Technique |
FT-Raman |
Zero Filling Factor |
4 |