4-Ethoxy-3-(trifluoromethyl)benzamide
SpectraBase Compound ID GdmOohIAuB5
InChI InChI=1S/C10H10F3NO2/c1-2-16-8-4-3-6(9(14)15)5-7(8)10(11,12)13/h3-5H,2H2,1H3,(H2,14,15)
InChIKey OQBNISNCGCRBHE-UHFFFAOYSA-N
Mol Weight 233.19 g/mol
Molecular Formula C10H10F3NO2
Exact Mass 233.066363 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID kuHzeLkbzZ
Name 4-Ethoxy-3-(trifluoromethyl)benzamide
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H33596
Lot Number 10180415
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 2690
Backward Peak Location 28691
Beam Splitter Setting Quartz
Calibration Lamp Spectrum Correction.0
Container ID C-009895
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C10H10F3NO2
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C10H10F3NO2/c1-2-16-8-4-3-6(9(14)15)5-7(8)10(11,12)13/h3-5H,2H2,1H3,(H2,14,15)
InChIKey OQBNISNCGCRBHE-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 233.190 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 250
Optical Filter Setting Open
Peak Amplitude 2620
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Preamplifier Gain 0
Purity 97%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU H33596-1G
SMILES NC(c1cc(c(cc1)OCC)C(F)(F)F)=O
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4