SpectraBase Spectrum ID |
QhWiMzBIXO |
Name |
(-)-4,5-Bis[hydroxy(diphenyl)methyl]-2,2-dimethyl-1,3-dioxolane |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
B1614 |
Lot Number |
57UFM-L0 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Additional Data Treatment |
1 |
Aperture Setting |
2.5 mm |
Apodization Function |
Norton-Beer, medium |
Backward Peak Amplitude |
1989 |
Backward Peak Location |
28691 |
Beam Splitter Setting |
Quartz |
CAS Registry Number |
93379-48-7 |
Calibration Lamp Spectrum |
Correction.0 |
Container ID |
C-009438 |
Copyright |
Copyright © 2017-2025 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
15 s |
Detector Setting |
LN-Ge Diode [Internal Pos.2] |
End Frequency Limit for File |
9394.3 |
External Analog Signals |
Off |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C31H30O4 |
Frequency of First Point |
3597.8 cm⁻¹ |
Frequency of Last Point |
-1.29183 cm⁻¹ |
High Folding Limit |
31596.8 |
High Frequency Limit |
30000 cm⁻¹ |
High Pass Filter |
1 |
InChI |
InChI=1S/C31H30O4/c1-29(2)34-27(30(32,23-15-7-3-8-16-23)24-17-9-4-10-18-24)28(35-29)31(33,25-19-11-5-12-20-25)26-21-13-6-14-22-26/h3-22,27-28,32-33H,1-2H3/t27-,28-/m1/s1 |
InChIKey |
OWVIRVJQDVCGQX-VSGBNLITSA-N |
Instrument Name |
Bruker MultiRAM Stand Alone FT-Raman Spectrometer |
Laser Wavenumber |
15798.4 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
5 |
Measurement Channel |
Raman Compartment |
Non Linearity Correction |
0 |
Number of Points |
7466 |
Number of Sample Scans |
250 |
Optical Filter Setting |
Open |
Peak Amplitude |
2030 |
Peak Location |
28693 |
Phase Correction Mode |
power spectrum |
Phase Resolution |
1 |
Physical State |
Solid |
Preamplifier Gain |
0 |
Purity |
97% |
Raman Background Corrected |
Yes |
Raman Corrections |
Referenced to internal light source; Scattering corrected |
Raman Laser Source |
Nd:YAG |
Raman Scattering Corrected |
Yes |
Resolution |
2 |
SKU |
B1614-1G |
SMILES |
OC([C@@]1(OC(O[C@]1(C(c1ccccc1)(c1ccccc1)O)[H])(C)C)[H])(c1ccccc1)c1ccccc1 |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
2 |
Scan Time |
0 s |
Scanner Velocity |
5 kHz |
Signal Gain, Sample |
2 |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
5794.76 cm⁻¹ |
Synonyms |
1,1,4,4-Tetraphenyl-2,3-O-isopropylidene-L-threitol |
Technique |
FT-Raman |
Zero Filling Factor |
4 |