For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
2-Fluoro-4-iodo-5-methylpyridine
SpectraBase Compound ID 2CqzILW5P9c
InChI InChI=1S/C6H5FIN/c1-4-3-9-6(7)2-5(4)8/h2-3H,1H3
InChIKey BVKQLNXPPQEELX-UHFFFAOYSA-N
Mol Weight 237.02 g/mol
Molecular Formula C6H5FIN
Exact Mass 236.945072 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID MkPycZL5HW
Name 2-Fluoro-4-iodo-5-methylpyridine
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number F1035
Lot Number J2NEJ-HC
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270204
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -8364
Backward Peak Location 14479
Beam Splitter Setting KBr
CAS Registry Number 153034-94-7
Color Properties Pale reddish yellow
Container ID C-009666
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C6H5FIN
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C6H5FIN/c1-4-3-9-6(7)2-5(4)8/h2-3H,1H3
InChIKey BVKQLNXPPQEELX-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 237.016 g/mol
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -8410
Peak Amplitude 2nd Channel 1
Peak Location 14476
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Solid
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 20 %
Resolution 2
SKU F1035-1G
SMILES c1c(ncc(c1I)C)F
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.051 s
Scanner Temperature 26.9 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique Melt (Crystalline)
Window KBr Window
Zero Filling Factor 8