Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID LobPuEONRhL
Name 4-Methyl-N-tosylbenzenesulfonamide
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number M2975
Lot Number KNYLG-SR
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 2957
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 3695-00-9
Calibration Lamp Spectrum Correction.0
Color Properties White
Container ID C-009704
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C14H15NO4S2
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C14H15NO4S2/c1-11-3-7-13(8-4-11)20(16,17)15-21(18,19)14-9-5-12(2)6-10-14/h3-10,15H,1-2H3
InChIKey LHWZLUXODWUHLZ-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 325.397 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 252
Optical Filter Setting Open
Peak Amplitude 2933
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU M2975-1G
SMILES N(S(c1ccc(cc1)C)(=O)=O)S(=O)(=O)c1ccc(cc1)C
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms Bis(4-methylbenzenesulfonyl)amine
Technique FT-Raman
Zero Filling Factor 4