SpectraBase Spectrum ID |
LVhoa4dHfKQ |
Name |
trans-N-(((9H-Fluoren-9-yl)methoxy)carbonyl)-4-hydroxy-L-proline |
Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
Catalog Number |
H52740 |
Lot Number |
K02W035 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Additional Data Treatment |
1 |
Aperture Setting |
2.5 mm |
Apodization Function |
Norton-Beer, medium |
Backward Peak Amplitude |
3896 |
Backward Peak Location |
28687 |
Beam Splitter Setting |
Quartz |
CAS Registry Number |
88050-17-3 |
Calibration Lamp Spectrum |
Correction.0 |
Color Properties |
White |
Container ID |
C-009775 |
Copyright |
Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
15 s |
Detector Setting |
LN-Ge Diode [Internal Pos.2] |
End Frequency Limit for File |
9394.3 |
External Analog Signals |
Off |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C20H19NO5 |
Frequency of First Point |
3597.79 cm⁻¹ |
Frequency of Last Point |
-1.31092 cm⁻¹ |
High Folding Limit |
31596.8 |
High Frequency Limit |
30000 cm⁻¹ |
High Pass Filter |
1 |
InChI |
InChI=1S/C20H19NO5/c22-12-9-18(19(23)24)21(10-12)20(25)26-11-17-15-7-3-1-5-13(15)14-6-2-4-8-16(14)17/h1-8,12,17-18,22H,9-11H2,(H,23,24)/t12-,18+/m1/s1 |
InChIKey |
GOUUPUICWUFXPM-XIKOKIGWSA-N |
Instrument Name |
Bruker MultiRAM Stand Alone FT-Raman Spectrometer |
Laser Wavenumber |
15798.4 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
5 |
Measurement Channel |
Raman Compartment |
Non Linearity Correction |
0 |
Number of Points |
7466 |
Number of Sample Scans |
254 |
Optical Filter Setting |
Open |
Peak Amplitude |
-3714 |
Peak Location |
28693 |
Phase Correction Mode |
power spectrum |
Phase Resolution |
1 |
Preamplifier Gain |
0 |
Purity |
97% |
Raman Background Corrected |
Yes |
Raman Corrections |
Referenced to internal light source; Scattering corrected |
Raman Laser Source |
Nd:YAG |
Raman Scattering Corrected |
Yes |
Resolution |
2 |
SKU |
H52740-1G |
SMILES |
O[C@]1(CN([C@](C(O)=O)(C1)[H])C(OCC1c2ccccc2-c2ccccc12)=O)[H] |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
2 |
Scan Time |
0 s |
Scanner Velocity |
5 kHz |
Signal Gain, Sample |
2 |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
5794.76 cm⁻¹ |
Synonyms |
(2S,4R)-1-(((9H-Fluoren-9-yl)methoxy)carbonyl)-4-hydroxypyrrolidine-2-carboxylic acid |
Technique |
FT-Raman |
Zero Filling Factor |
4 |