For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
2-Bromo-6-chloro-4-fluoroaniline
SpectraBase Compound ID 4zrxWyGpqpg
InChI InChI=1S/C6H4BrClFN/c7-4-1-3(9)2-5(8)6(4)10/h1-2H,10H2
InChIKey LIBGMUMMWYKJSC-UHFFFAOYSA-N
Mol Weight 224.46 g/mol
Molecular Formula C6H4BrClFN
Exact Mass 222.919968 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID LUM64DmGXYp
Name 2-Bromo-6-chloro-4-fluoroaniline
Source of Sample Acros Organics
Catalog Number 398440010
Lot Number A0275227
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270444
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -7343
Backward Peak Location 14480
Beam Splitter Setting KBr
CAS Registry Number 201849-14-1
Color Properties Beige to brown
Container ID C-008596
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C6H4BrClFN
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C6H4BrClFN/c7-4-1-3(9)2-5(8)6(4)10/h1-2H,10H2
InChIKey LIBGMUMMWYKJSC-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 224.460 g/mol
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -7504
Peak Amplitude 2nd Channel 1
Peak Location 14476
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Solid
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 20 %
Resolution 2
SKU 398440010-1GR
SMILES Nc1c(cc(cc1Cl)F)Br
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.044 s
Scanner Temperature 28.8 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Solvent Dichloromethane
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique Film
Window KBr Window
Zero Filling Factor 8