For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
4-Amino-3-(trifluoromethyl)benzoic acid
SpectraBase Compound ID 2EdgQ5K3byu
InChI InChI=1S/C8H6F3NO2/c9-8(10,11)5-3-4(7(13)14)1-2-6(5)12/h1-3H,12H2,(H,13,14)
InChIKey NPPPORJZPNJXNQ-UHFFFAOYSA-N
Mol Weight 205.14 g/mol
Molecular Formula C8H6F3NO2
Exact Mass 205.035063 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID LHWGHGU9IFt
Name 4-Amino-3-(trifluoromethyl)benzoic acid
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H32487
Lot Number 10162532
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 4394
Backward Peak Location 28687
Beam Splitter Setting Quartz
CAS Registry Number 400-76-0
Calibration Lamp Spectrum Correction.0
Container ID C-009821
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C8H6F3NO2
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C8H6F3NO2/c9-8(10,11)5-3-4(7(13)14)1-2-6(5)12/h1-3H,12H2,(H,13,14)
InChIKey NPPPORJZPNJXNQ-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 205.136 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 254
Optical Filter Setting Open
Peak Amplitude -4288
Peak Location 28693
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU H32487-1G
SMILES OC(c1cc(c(cc1)N)C(F)(F)F)=O
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4