For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
3,4,6-TRIS-O-TERT.BUTYLDIMETHYLSILYL-D-GLUCAL
SpectraBase Compound ID 8sZL70FL9UV
InChI InChI=1S/C24H52O4Si3/c1-22(2,3)29(10,11)26-18-20-21(28-31(14,15)24(7,8)9)19(16-17-25-20)27-30(12,13)23(4,5)6/h16-17,19-21H,18H2,1-15H3/t19-,20-,21+/m1/s1
InChIKey FMXIGEXRLSNRMR-NJYVYQBISA-N
Mol Weight 488.9 g/mol
Molecular Formula C24H52O4Si3
Exact Mass 488.31734 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID LG7QLXGQfHQ
Name 3,4,6-Tri-O-tert-butyldimethylsilyl-D-glucal
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H60275
Lot Number B15Z021
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270386
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1940
Backward Peak Location 7369
Beam Splitter Setting KBr
CAS Registry Number 79999-47-6
Color Properties Colorless
Container ID C-010016
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C24H52O4Si3
Frequency of First Point 3998.34 cm⁻¹
Frequency of Last Point 339.463 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C24H52O4Si3/c1-22(2,3)29(10,11)26-18-20-21(28-31(14,15)24(7,8)9)19(16-17-25-20)27-30(12,13)23(4,5)6/h16-17,19-21H,18H2,1-15H3/t19-,20-,21+/m1/s1
InChIKey FMXIGEXRLSNRMR-NJYVYQBISA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1966
Peak Amplitude 2nd Channel 1
Peak Location 7366
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Liquid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 97%
Relative Humidity Interferometer 10 %
Resolution 4
SKU H60275-1G
SMILES [C@]1(\C=C/O[C@@]([C@]1(O[Si](C)(C)C(C)(C)C)[H])(CO[Si](C)(C)C(C)(C)C)[H])(O[Si](C)(C)C(C)(C)C)[H]
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.296 s
Scanner Temperature 28.3 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique ATR-Neat
Zero Filling Factor 4