6-AMINO-5-CHLORO-alpha,alpha,alpha-TRIFLUORO-3-PICOLINE
SpectraBase Compound ID 9Wzyay48VwW
InChI InChI=1S/C6H4ClF3N2/c7-4-1-3(6(8,9)10)2-12-5(4)11/h1-2H,(H2,11,12)
InChIKey WXNPZQIRDCDLJD-UHFFFAOYSA-N
Mol Weight 196.56 g/mol
Molecular Formula C6H4ClF3N2
Exact Mass 196.00151 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID LFRsEPwWte
Name 2-Amino-3-chloro-5-trifluoromethylpyridine
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number A1157
Lot Number GF3XI-HB
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270522
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -7453
Backward Peak Location 14458
Beam Splitter Setting KBr
CAS Registry Number 79456-26-1
Color Properties White to off-white
Container ID C-010292
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C6H4ClF3N2
Frequency of First Point 3999.74 cm⁻¹
Frequency of Last Point 339.942 cm⁻¹
High Folding Limit 15800.3
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C6H4ClF3N2/c7-4-1-3(6(8,9)10)2-12-5(4)11/h1-2H,(H2,11,12)
InChIKey WXNPZQIRDCDLJD-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.3 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 196.560 g/mol
Non Linearity Correction 0
Number of Points 15181
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -6911
Peak Amplitude 2nd Channel 1
Peak Location 14498
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Solid
Preamplifier Gain Background 0
Purity >98.0%
Relative Humidity Interferometer 0 %
Resolution 2
SKU A1157-5G
SMILES FC(F)(F)c1cc(c(nc1)N)Cl
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.1 s
Scanner Temperature 30.5 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms N-(3,4-Dimethoxyphenyl)-1-(5-phenylpyrimidin-2-yl)piperidine-3-carboxamide
Technique KBr0
Zero Filling Factor 8