For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
2-(4-Morpholinyl)pyridine
SpectraBase Compound ID 4EWxduKUZEl
InChI InChI=1S/C9H12N2O/c1-2-4-10-9(3-1)11-5-7-12-8-6-11/h1-4H,5-8H2
InChIKey XHPVOSNOIWGRQQ-UHFFFAOYSA-N
Mol Weight 164.21 g/mol
Molecular Formula C9H12N2O
Exact Mass 164.094963 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID Kxj7vh4ZOsQ
Name 2-(4-Morpholinyl)pyridine
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H55989
Lot Number 5006F19P
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 4685
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 24255-25-2
Calibration Lamp Spectrum Correction.0
Container ID C-010002
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C9H12N2O
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C9H12N2O/c1-2-4-10-9(3-1)11-5-7-12-8-6-11/h1-4H,5-8H2
InChIKey XHPVOSNOIWGRQQ-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 164.208 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 4
Optical Filter Setting Open
Peak Amplitude 4515
Peak Location 28693
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Liquid
Preamplifier Gain 0
Purity 96%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU H55989-1G
SMILES C1COCCN1c1ncccc1
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 2-Morpholinopyridine
Technique FT-Raman
Zero Filling Factor 4