SpectraBase Spectrum ID |
KbECZkLWQbk |
Name |
4-Bromo-2-fluoro-5-(trifluoromethyl)aniline |
Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
Catalog Number |
H31727 |
Lot Number |
10158106 |
Accessory |
TRANS *14560FA0 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
0 |
Analog Signal 1 |
0.270484 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-10332 |
Backward Peak Location |
14490 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
104460-70-0 |
Container ID |
C-009826 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
0 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C7H4BrF4N |
Frequency of First Point |
3999.54 cm⁻¹ |
Frequency of Last Point |
339.945 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C7H4BrF4N/c8-4-2-5(9)6(13)1-3(4)7(10,11)12/h1-2H,13H2 |
InChIKey |
UYVDMCXPDGRLEC-UHFFFAOYSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Molecular Weight |
258.014 g/mol |
Non Linearity Correction |
0 |
Number of Points |
15180 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-10191 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
14465 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
4 |
Physical State |
Solid |
Preamplifier Gain Background |
0 |
Purity |
97% |
Relative Humidity Interferometer |
0 % |
Resolution |
2 |
SKU |
H31727-1G |
SMILES |
FC(F)(F)c1c(cc(c(c1)N)F)Br |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
50.047 s |
Scanner Temperature |
29.2 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
5-Amino-2-bromo-4-fluorobenzotrifluoride |
Technique |
Melt (Liquid) |
Window |
KBr Window |
Zero Filling Factor |
8 |