3,4,5-Trifluorobenzophenone
SpectraBase Compound ID HZtxIVWDWTN
InChI InChI=1S/C13H7F3O/c14-10-6-9(7-11(15)12(10)16)13(17)8-4-2-1-3-5-8/h1-7H
InChIKey BTQOMZVQASIULU-UHFFFAOYSA-N
Mol Weight 236.19 g/mol
Molecular Formula C13H7F3O
Exact Mass 236.044899 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID KY0PhJdFqOF
Name 3,4,5-Trifluorobenzophenone
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H26727
Lot Number 10137845
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 2488
Backward Peak Location 28687
Beam Splitter Setting Quartz
CAS Registry Number 70028-88-5
Calibration Lamp Spectrum Correction.0
Color Properties White
Container ID C-009851
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C13H7F3O
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C13H7F3O/c14-10-6-9(7-11(15)12(10)16)13(17)8-4-2-1-3-5-8/h1-7H
InChIKey BTQOMZVQASIULU-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 236.193 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 256
Optical Filter Setting Open
Peak Amplitude -2460
Peak Location 28693
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Liquid
Preamplifier Gain 0
Purity 97%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU H26727-1G
SMILES c1ccccc1C(c1cc(c(c(c1)F)F)F)=O
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4