For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
2,5-dichloro-3-thienyl methyl ester
SpectraBase Compound ID ITdFGiqMPlQ
InChI InChI=1S/C6H4Cl2OS/c1-3(9)4-2-5(7)10-6(4)8/h2H,1H3
InChIKey GYFDNIRENHZKGR-UHFFFAOYSA-N
Mol Weight 195.06 g/mol
Molecular Formula C6H4Cl2OS
Exact Mass 193.935991 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID KWuaP5qKi3t
Name 3-Acetyl-2,5-dichlorothiophene
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number A1182
Lot Number WDK6A-BD
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 16
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270642
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1596
Backward Peak Location 7349
Beam Splitter Setting KBr
CAS Registry Number 36157-40-1
Color Properties Tan
Container ID C-010210
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C6H4Cl2OS
Frequency of First Point 3998.29 cm⁻¹
Frequency of Last Point 339.459 cm⁻¹
High Folding Limit 15800.3
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C6H4Cl2OS/c1-3(9)4-2-5(7)10-6(4)8/h2H,1H3
InChIKey GYFDNIRENHZKGR-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.3 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1734
Peak Amplitude 2nd Channel 1
Peak Location 7387
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Solid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity >98.0%
Relative Humidity Interferometer 20 %
Resolution 4
SKU A1182-5G
SMILES c1c(sc(c1C(C)=O)Cl)Cl
Sample Comments Sample ground at metal edge of ATR
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.331 s
Scanner Temperature 28.5 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms 2,5-Dichloro-3-thienyl methyl ketone
Technique ATR-Neat
Zero Filling Factor 4