SpectraBase Spectrum ID |
KQWvGYj2qzu |
Name |
Nα-[(9H-Fluoren-9-ylmethoxy)carbonyl]-tele-(triphenylmethyl)-D-histidine |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
F1145 |
Lot Number |
QW7FD-BT |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Additional Data Treatment |
1 |
Aperture Setting |
2.5 mm |
Apodization Function |
Norton-Beer, medium |
Backward Peak Amplitude |
1349 |
Backward Peak Location |
28691 |
Beam Splitter Setting |
Quartz |
CAS Registry Number |
135610-90-1 |
Calibration Lamp Spectrum |
Correction.0 |
Color Properties |
White- pale reddish yellow |
Container ID |
C-009730 |
Copyright |
Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
15 s |
Detector Setting |
LN-Ge Diode [Internal Pos.2] |
End Frequency Limit for File |
9394.3 |
External Analog Signals |
Off |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C40H33N3O4 |
Frequency of First Point |
3597.79 cm⁻¹ |
Frequency of Last Point |
-1.31092 cm⁻¹ |
High Folding Limit |
31596.8 |
High Frequency Limit |
30000 cm⁻¹ |
High Pass Filter |
1 |
InChI |
InChI=1S/C40H33N3O4/c44-38(45)37(42-39(46)47-26-36-34-22-12-10-20-32(34)33-21-11-13-23-35(33)36)24-31-25-43(27-41-31)40(28-14-4-1-5-15-28,29-16-6-2-7-17-29)30-18-8-3-9-19-30/h1-23,25,27,36-37H,24,26H2,(H,42,46)(H,44,45)/t37-/m1/s1 |
InChIKey |
XXMYDXUIZKNHDT-DIPNUNPCSA-N |
Instrument Name |
Bruker MultiRAM Stand Alone FT-Raman Spectrometer |
Laser Wavenumber |
15798.4 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
5 |
Measurement Channel |
Raman Compartment |
Molecular Weight |
619.721 g/mol |
Non Linearity Correction |
0 |
Number of Points |
7466 |
Number of Sample Scans |
416 |
Optical Filter Setting |
Open |
Peak Amplitude |
1343 |
Peak Location |
28692 |
Phase Correction Mode |
power spectrum |
Phase Resolution |
1 |
Physical State |
Solid |
Preamplifier Gain |
0 |
Purity |
97% |
Raman Background Corrected |
Yes |
Raman Corrections |
Referenced to internal light source; Scattering corrected |
Raman Laser Source |
Nd:YAG |
Raman Scattering Corrected |
Yes |
Resolution |
2 |
SKU |
F1145-1G |
SMILES |
N([C@@](C(O)=O)(Cc1nc[n](c1)C(c1ccccc1)(c1ccccc1)c1ccccc1)[H])C(OCC1c2ccccc2-c2ccccc12)=O |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
2 |
Scan Time |
0 s |
Scanner Velocity |
5 kHz |
Signal Gain, Sample |
2 |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
5794.76 cm⁻¹ |
Synonyms |
N-[(9H-Fluoren-9-yl-methoxy)carbonyl]-1-trityl-D-histidine |
Technique |
FT-Raman |
Zero Filling Factor |
4 |