SpectraBase Spectrum ID |
KPMgsPsDWhg |
Name |
Cytidine 5'-monophosphate |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
C1675 |
Lot Number |
TA3NN-ME |
Accessory |
DuraSample IR #145404C7 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
8 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
1 |
Analog Signal 1 |
0.2702 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Rotations |
32 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-1740 |
Backward Peak Location |
7369 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
63-37-6 |
Color Properties |
White |
Container ID |
C-009517 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
1 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C9H14N3O8P |
Frequency of First Point |
3998.34 cm⁻¹ |
Frequency of Last Point |
339.463 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C9H14N3O8P/c10-5-1-2-12(9(15)11-5)8-7(14)6(13)4(20-8)3-19-21(16,17)18/h1-2,4,6-8,13-14H,3H2,(H2,10,11,15)(H2,16,17,18)/t4-,6-,7-,8-/m1/s1 |
InChIKey |
IERHLVCPSMICTF-XVFCMESISA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Measurement Channel |
Sample Compartment |
Non Linearity Correction |
0 |
Number of Points |
3795 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-1744 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
7366 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
8 |
Physical State |
Liquid |
Preamplifier Gain |
3 |
Preamplifier Gain Background |
0 |
Purity |
98% |
Relative Humidity Interferometer |
20 % |
Resolution |
4 |
SKU |
C1675-1G |
SMILES |
N\C=1\C=C/N([C@@]2(O[C@@]([C@]([C@]2(O)[H])(O)[H])(COP(O)(=O)O)[H])[H])C(N\1)=O |
Sample Comments |
Sample ground at metal edge of ATR |
Sample Rotations |
32 |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
27.296 s |
Scanner Temperature |
25.9 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Signal Gain, Sample |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
5'-Cytidylic acid |
Technique |
ATR-Neat |
Zero Filling Factor |
4 |