Methyl 3-(2-bromophenyl)propionate
SpectraBase Compound ID 52CAAAnR2Yp
InChI InChI=1S/C10H11BrO2/c1-13-10(12)7-6-8-4-2-3-5-9(8)11/h2-5H,6-7H2,1H3
InChIKey NIULOVGPRAJIJM-UHFFFAOYSA-N
Mol Weight 243.1 g/mol
Molecular Formula C10H11BrO2
Exact Mass 241.994243 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID K16mzqeEz6M
Name Methyl 3-(2-bromophenyl)propionate
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number M2587
Lot Number QM4AI-OS
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270331
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1907
Backward Peak Location 7370
Beam Splitter Setting KBr
CAS Registry Number 66191-86-4
Color Properties Colorless
Container ID C-009720
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C10H11BrO2
Frequency of First Point 3998.34 cm⁻¹
Frequency of Last Point 339.463 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C10H11BrO2/c1-13-10(12)7-6-8-4-2-3-5-9(8)11/h2-5H,6-7H2,1H3
InChIKey NIULOVGPRAJIJM-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1856
Peak Amplitude 2nd Channel 1
Peak Location 7366
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Liquid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 20 %
Resolution 4
SKU M2587-1G
SMILES c1c(c(ccc1)Br)CCC(OC)=O
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.309 s
Scanner Temperature 28 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique ATR-Neat
Zero Filling Factor 4