For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
3,5-Dibromo-1,2,4-triazole
SpectraBase Compound ID 2HgI0RnvdQ4
InChI InChI=1S/C2HBr2N3/c3-1-5-2(4)7-6-1/h(H,5,6,7)
InChIKey FRAKFBWDPXYIQO-UHFFFAOYSA-N
Mol Weight 226.859 g/mol
Molecular Formula C2HBr2N3
Exact Mass 224.853723 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID JvWRg44puUt
Name 3,5-Dibromo-1,2,4-triazole
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number D5030
Lot Number TGMNI-TF
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 16
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270509
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1378
Backward Peak Location 7369
Beam Splitter Setting KBr
CAS Registry Number 7411-23-6
Color Properties White-plae reddish yellow
Container ID C-010437
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C2HBr2N3
Frequency of First Point 3998.31 cm⁻¹
Frequency of Last Point 339.461 cm⁻¹
High Folding Limit 15800.4
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C2HBr2N3/c3-1-5-2(4)7-6-1/h(H,5,6,7)
InChIKey FRAKFBWDPXYIQO-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1415
Peak Amplitude 2nd Channel 1
Peak Location 7366
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Solid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity >97.0%
Relative Humidity Interferometer 10 %
Resolution 4
SKU D5030-5G
SMILES [nH]1nc(nc1Br)Br
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.303 s
Scanner Temperature 29.6 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique ATR-Neat
Zero Filling Factor 4