Pentafluorophenyl benzoate
SpectraBase Compound ID A4rF0dc5bDo
InChI InChI=1S/C13H5F5O2/c14-7-8(15)10(17)12(11(18)9(7)16)20-13(19)6-4-2-1-3-5-6/h1-5H
InChIKey WZPWTXZSQHIABL-UHFFFAOYSA-N
Mol Weight 288.17 g/mol
Molecular Formula C13H5F5O2
Exact Mass 288.02097 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID JfAwQqrgQ2J
Name Pentafluorophenyl benzoate
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number P2229
Lot Number 8FYBK-LS
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 1912
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 1548-84-1
Calibration Lamp Spectrum Correction.0
Color Properties White
Container ID C-009446
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C13H5F5O2
Frequency of First Point 3597.8 cm⁻¹
Frequency of Last Point -1.29183 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C13H5F5O2/c14-7-8(15)10(17)12(11(18)9(7)16)20-13(19)6-4-2-1-3-5-6/h1-5H
InChIKey WZPWTXZSQHIABL-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 288.173 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 248
Optical Filter Setting Open
Peak Amplitude 1877
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU P2229-1G
SMILES c1(c(c(c(c(c1F)F)F)F)F)OC(c1ccccc1)=O
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4