For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
Anthranilic acid benzyl ester
SpectraBase Compound ID 2f21Xi2954A
InChI InChI=1S/C14H13NO2/c15-13-9-5-4-8-12(13)14(16)17-10-11-6-2-1-3-7-11/h1-9H,10,15H2
InChIKey ZHZPDMZPDWXVMJ-UHFFFAOYSA-N
Mol Weight 227.26 g/mol
Molecular Formula C14H13NO2
Exact Mass 227.094629 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID JejH3ET8J8S
Name Benzyl anthranilate
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number B5249
Lot Number GZPRD-JJ
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 1837
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 82185-41-9
Calibration Lamp Spectrum Correction.0
Color Properties White-pale reddish yellow
Container ID C-009616
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C14H13NO2
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C14H13NO2/c15-13-9-5-4-8-12(13)14(16)17-10-11-6-2-1-3-7-11/h1-9H,10,15H2
InChIKey ZHZPDMZPDWXVMJ-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 227.263 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 234
Optical Filter Setting Open
Peak Amplitude 1824
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU B5249-1G
SMILES Nc1ccccc1C(OCc1ccccc1)=O
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 2-Aminobenzoic acid benzyl ester; Anthranilic acid benzyl ester
Technique FT-Raman
Zero Filling Factor 4