SpectraBase Spectrum ID |
J7i08LQjmmq |
Name |
9,9-Bis(4-amino-3-methylphenyl)fluorene |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
B2693 |
Lot Number |
W8IRG-EK |
Accessory |
DuraSample IR #145404C7 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
16 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
1 |
Analog Signal 1 |
0.270555 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Rotations |
32 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-1504 |
Backward Peak Location |
7348 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
107934-60-1 |
Color Properties |
White - Very pale yellow |
Container ID |
C-010220 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
1 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C27H24N2 |
Frequency of First Point |
3998.29 cm⁻¹ |
Frequency of Last Point |
339.459 cm⁻¹ |
High Folding Limit |
15800.3 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C27H24N2/c1-17-15-19(11-13-25(17)28)27(20-12-14-26(29)18(2)16-20)23-9-5-3-7-21(23)22-8-4-6-10-24(22)27/h3-16H,28-29H2,1-2H3 |
InChIKey |
YRKVLGUIGNRYJX-UHFFFAOYSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.3 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Measurement Channel |
Sample Compartment |
Molecular Weight |
376.503 g/mol |
Non Linearity Correction |
0 |
Number of Points |
3795 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-1537 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
7387 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
8 |
Physical State |
Solid |
Preamplifier Gain |
3 |
Preamplifier Gain Background |
0 |
Purity |
>98.0% |
Relative Humidity Interferometer |
0 % |
Resolution |
4 |
SKU |
B2693-5G |
SMILES |
Nc1c(cc(C2(c3ccc(c(c3)C)N)c3ccccc3-c3ccccc23)cc1)C |
Sample Comments |
Sample ground at metal edge of ATR |
Sample Rotations |
32 |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
27.327 s |
Scanner Temperature |
29.3 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Signal Gain, Sample |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
2,2'-Dimethyl-4,4'-(9-fluorenylidene)dianiline; 4,4'-(9-Fluorenylidene)di-o-toluidine |
Technique |
ATR-Neat |
Zero Filling Factor |
4 |