SpectraBase Spectrum ID |
IxW0KDxQ1CU |
Name |
N-[(9H-Fluoren-9-ylmethoxy)carbonyl]-O-tert-butyl-D-threonine |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
F1128 |
Lot Number |
RD6AI-DA |
Accessory |
DuraSample IR #145404C7 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
8 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
1 |
Analog Signal 1 |
0.270311 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Rotations |
32 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-1867 |
Backward Peak Location |
7372 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
138797-71-4 |
Color Properties |
Light yellow |
Container ID |
C-009668 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
1 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C23H27NO5 |
Frequency of First Point |
3998.34 cm⁻¹ |
Frequency of Last Point |
339.463 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C23H27NO5/c1-14(29-23(2,3)4)20(21(25)26)24-22(27)28-13-19-17-11-7-5-9-15(17)16-10-6-8-12-18(16)19/h5-12,14,19-20H,13H2,1-4H3,(H,24,27)(H,25,26)/t14-,20+/m0/s1 |
InChIKey |
LZOLWEQBVPVDPR-VBKZILBWSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Measurement Channel |
Sample Compartment |
Non Linearity Correction |
0 |
Number of Points |
3795 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-1861 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
7364 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
8 |
Physical State |
Solid |
Preamplifier Gain |
3 |
Preamplifier Gain Background |
0 |
Purity |
98% |
Relative Humidity Interferometer |
20 % |
Resolution |
4 |
SKU |
F1128-1G |
SMILES |
OC([C@@]([C@](C)(OC(C)(C)C)[H])(NC(OCC1c2ccccc2-c2ccccc12)=O)[H])=O |
Sample Comments |
Sample ground at metal edge of ATR |
Sample Rotations |
32 |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
27.311 s |
Scanner Temperature |
26.4 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Signal Gain, Sample |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
(2S)-2-((((9H-Fluoren-9-yl)methoxy)carbonyl)amino)-3-(tert-butoxy)butanoic acid |
Technique |
ATR-Neat |
Zero Filling Factor |
4 |