For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
Methyl 4-amino-3-methylbenzoate
SpectraBase Compound ID BVtGu96hKM8
InChI InChI=1S/C9H11NO2/c1-6-5-7(9(11)12-2)3-4-8(6)10/h3-5H,10H2,1-2H3
InChIKey ZHIPSMIKSRYZFV-UHFFFAOYSA-N
Mol Weight 165.19 g/mol
Molecular Formula C9H11NO2
Exact Mass 165.078979 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID IVuCelCz2n6
Name Methyl 4-amino-3-methylbenzoate
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number M2152
Lot Number WBFFJ-TD
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 16
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270534
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1353
Backward Peak Location 7370
Beam Splitter Setting KBr
CAS Registry Number 18595-14-7
Color Properties Yellow-red
Container ID C-010411
Copyright Copyright © 2018-2025 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C9H11NO2
Frequency of First Point 3998.31 cm⁻¹
Frequency of Last Point 339.461 cm⁻¹
High Folding Limit 15800.4
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C9H11NO2/c1-6-5-7(9(11)12-2)3-4-8(6)10/h3-5H,10H2,1-2H3
InChIKey ZHIPSMIKSRYZFV-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1310
Peak Amplitude 2nd Channel 1
Peak Location 7366
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Solid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity >98.0%
Relative Humidity Interferometer 20 %
Resolution 4
SKU M2152-5G
SMILES Nc1c(cc(cc1)C(OC)=O)C
Sample Comments Sample ground at metal edge of ATR
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.301 s
Scanner Temperature 29 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms 4-Amino-3-methylbenzoic acid methyl ester; Methyl 4-amino-m-toluate
Technique ATR-Neat
Zero Filling Factor 4