For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
L-Valine tert-butyl ester hydrochloride
SpectraBase Compound ID 5XWh2FXtibg
InChI InChI=1S/C9H19NO2.ClH/c1-6(2)7(10)8(11)12-9(3,4)5;/h6-7H,10H2,1-5H3;1H/t7-;/m0./s1
InChIKey AUIVQIHTTVPKFS-FJXQXJEOSA-N
Mol Weight 209.72 g/mol
Molecular Formula C9H20ClNO2
Exact Mass 209.118257 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID IPlPgyoKF35
Name L-Valine tert-butyl ester hydrochloride
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H56207
Lot Number 81200974
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270508
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1901
Backward Peak Location 7340
Beam Splitter Setting KBr
CAS Registry Number 13518-40-6
Color Properties White
Container ID C-009764
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C9H20ClNO2
Frequency of First Point 3998.34 cm⁻¹
Frequency of Last Point 339.463 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C9H19NO2.ClH/c1-6(2)7(10)8(11)12-9(3,4)5;/h6-7H,10H2,1-5H3;1H/t7-;/m0./s1
InChIKey AUIVQIHTTVPKFS-FJXQXJEOSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Molecular Weight 209.717 g/mol
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1915
Peak Amplitude 2nd Channel 1
Peak Location 7396
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Liquid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 97%
Relative Humidity Interferometer 0 %
Resolution 4
SKU H56207-1G
SMILES Cl.N[C@](C(OC(C)(C)C)=O)(C(C)C)[H]
Sample Comments Sample ground at metal edge of ATR
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.293 s
Scanner Temperature 28.2 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms (S)-tert-Butyl 2-amino-3-methylbutanoate hydrochloride
Technique ATR-Neat
Zero Filling Factor 4