SpectraBase Spectrum ID |
HvC2SqVHebz |
Name |
Ethyl 3-acetoxyhexanoate |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
E1014 |
Lot Number |
YDYZD-QJ |
Accessory |
TRANS *14560FA0 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
0 |
Analog Signal 1 |
0.270545 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Scans |
16 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-8428 |
Backward Peak Location |
14480 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
21188-61-4 |
Color Properties |
Colorless |
Container ID |
C-010370 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
0 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C10H18O4 |
Frequency of First Point |
3999.76 cm⁻¹ |
Frequency of Last Point |
339.943 cm⁻¹ |
High Folding Limit |
15800.4 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C10H18O4/c1-4-6-9(14-8(3)11)7-10(12)13-5-2/h9H,4-7H2,1-3H3 |
InChIKey |
UYBMIHNGXIOMAW-UHFFFAOYSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.4 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Molecular Weight |
202.250 g/mol |
Non Linearity Correction |
0 |
Number of Points |
15181 |
Number of Sample Scans |
16 |
Optical Filter Setting |
Open |
Peak Amplitude |
-8363 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
14476 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
4 |
Physical State |
Liquid |
Preamplifier Gain Background |
0 |
Purity |
>98.0% |
Relative Humidity Interferometer |
0 % |
Resolution |
2 |
SKU |
E1014-5G |
SMILES |
CCCC(CC(OCC)=O)OC(C)=O |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
24.993 s |
Scanner Temperature |
29.7 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
3-Acetoxyhexanoic acid ethyl ester |
Technique |
Neat |
Window |
KBr Window - 1 Side |
Zero Filling Factor |
8 |