For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
Ethyl 4-quinazolone-2-carboxylate
SpectraBase Compound ID 1lhpwovXh4Q
InChI InChI=1S/C11H10N2O3/c1-2-16-11(15)9-12-8-6-4-3-5-7(8)10(14)13-9/h3-6H,2H2,1H3,(H,12,13,14)
InChIKey BMCAWNQKVVTNFP-UHFFFAOYSA-N
Mol Weight 218.21 g/mol
Molecular Formula C11H10N2O3
Exact Mass 218.069142 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID HuKYdKxAmFZ
Name Ethyl 4-quinazolone-2-carboxylate
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number L06709
Lot Number LF003960
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270518
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -12102
Backward Peak Location 14480
Beam Splitter Setting KBr
CAS Registry Number 29113-33-5
Color Properties Yellow
Container ID C-008094
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C11H10N2O3
Frequency of First Point 3999.75 cm⁻¹
Frequency of Last Point 339.942 cm⁻¹
High Folding Limit 15800.3
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C11H10N2O3/c1-2-16-11(15)9-12-8-6-4-3-5-7(8)10(14)13-9/h3-6H,2H2,1H3,(H,12,13,14)
InChIKey BMCAWNQKVVTNFP-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.3 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Non Linearity Correction 0
Number of Points 15181
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -11691
Peak Amplitude 2nd Channel 1
Peak Location 14476
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Solid
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 10 %
Resolution 2
SKU L06709-1G
SMILES N1C(c2ccccc2\N=C/1C(OCC)=O)=O
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.055 s
Scanner Temperature 30 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Solvent Dichloromethane
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms 4-Quinazolone-2-carboxylic acid ethyl ester; 4-Oxo-3,4-dihydro-quinazoline-2-carboxylic acid ethyl ester
Technique Film
Window KBr Window
Zero Filling Factor 8