SpectraBase Spectrum ID |
HtM1kHEQWRX |
Name |
3,4,5-Trimethoxyphenyl isocyanate |
Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
Catalog Number |
L09775 |
Lot Number |
10150602 |
Accessory |
TRANS *14560FA0 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
0 |
Analog Signal 1 |
0.270427 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-10818 |
Backward Peak Location |
14490 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
1016-19-9 |
Container ID |
C-009901 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
0 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C10H11NO4 |
Frequency of First Point |
3999.54 cm⁻¹ |
Frequency of Last Point |
339.945 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C10H11NO4/c1-13-8-4-7(11-6-12)5-9(14-2)10(8)15-3/h4-5H,1-3H3 |
InChIKey |
MJJXWPHZDBIHIM-UHFFFAOYSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Molecular Weight |
209.201 g/mol |
Non Linearity Correction |
0 |
Number of Points |
15180 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-10263 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
14466 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
4 |
Physical State |
Solid |
Preamplifier Gain Background |
0 |
Purity |
97% |
Relative Humidity Interferometer |
0 % |
Resolution |
2 |
SKU |
L09775-1G |
SMILES |
c1c(c(c(cc1N=C=O)OC)OC)OC |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
50.048 s |
Scanner Temperature |
28.6 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
5-Isocyanato-1,2,3-trimethoxybenzene |
Technique |
Melt (Liquid) |
Window |
KBr Window |
Zero Filling Factor |
8 |