For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
YJKHMSPWWGBKTN-UHFFFAOYSA-N
SpectraBase Compound ID JN5GxLNrYiG
InChI InChI=1S/C11H8F12O2/c1-4(2)5(24)25-3-7(14,15)9(18,19)11(22,23)10(20,21)8(16,17)6(12)13/h6H,1,3H2,2H3
InChIKey YJKHMSPWWGBKTN-UHFFFAOYSA-N
Mol Weight 400.16 g/mol
Molecular Formula C11H8F12O2
Exact Mass 400.033267 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID Hcw3plUGC4C
Name 2,2,3,3,4,4,5,5,6,6,7,7-Dodecafluoroheptyl methacrylate
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number D4990
Lot Number 5ZHKE-QR
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 16
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270554
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1424
Backward Peak Location 7370
Beam Splitter Setting KBr
CAS Registry Number 2261-99-6
Color Properties White-pale yellow
Comments stabilized with TBC
Container ID C-010424
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C11H8F12O2
Frequency of First Point 3998.31 cm⁻¹
Frequency of Last Point 339.461 cm⁻¹
High Folding Limit 15800.4
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C11H8F12O2/c1-4(2)5(24)25-3-7(14,15)9(18,19)11(22,23)10(20,21)8(16,17)6(12)13/h6H,1,3H2,2H3
InChIKey YJKHMSPWWGBKTN-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1387
Peak Amplitude 2nd Channel 1
Peak Location 7366
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Liquid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity >97.0%
Relative Humidity Interferometer 10 %
Resolution 4
SKU D4990-5G
SMILES CC(C(OCC(C(C(C(C(C(F)F)(F)F)(F)F)(F)F)(F)F)(F)F)=O)=C
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.302 s
Scanner Temperature 29.4 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique ATR-Neat
Zero Filling Factor 4