For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
N-Succinimidyl N-methylcarbamate
SpectraBase Compound ID 3ABw5XJzhci
InChI InChI=1S/C6H8N2O4/c1-7-6(11)12-8-4(9)2-3-5(8)10/h2-3H2,1H3,(H,7,11)
InChIKey XMNGSPOWUCNRMO-UHFFFAOYSA-N
Mol Weight 172.14 g/mol
Molecular Formula C6H8N2O4
Exact Mass 172.048407 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID HbSoDOfQaxu
Name N-Succinimidyl N-methylcarbamate
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H63566
Lot Number 81600011
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 1985
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 18342-66-0
Calibration Lamp Spectrum Correction.0
Container ID C-009862
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C6H8N2O4
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C6H8N2O4/c1-7-6(11)12-8-4(9)2-3-5(8)10/h2-3H2,1H3,(H,7,11)
InChIKey XMNGSPOWUCNRMO-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 232
Optical Filter Setting Open
Peak Amplitude -1946
Peak Location 28689
Phase Correction Mode power spectrum
Phase Resolution 1
Preamplifier Gain 0
Purity 97%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU H63566-1G
SMILES N(C(ON1C(CCC1=O)=O)=O)C
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 2,5-Dioxopyrrolidin-1-yl methylcarbamate
Technique FT-Raman
Zero Filling Factor 4