2-Bromo-3-dodecylthiophene
SpectraBase Compound ID LaFIU2SMKP0
InChI InChI=1S/C16H27BrS/c1-2-3-4-5-6-7-8-9-10-11-12-15-13-14-18-16(15)17/h13-14H,2-12H2,1H3
InChIKey IMILVTHOOISGRW-UHFFFAOYSA-N
Mol Weight 331.36 g/mol
Molecular Formula C16H27BrS
Exact Mass 330.101685 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID HYY6baGbXDO
Name 2-Bromo-3-dodecylthiophene
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number B3691
Lot Number Q5WKL-PE
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270418
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1968
Backward Peak Location 7372
Beam Splitter Setting KBr
CAS Registry Number 139100-06-4
Color Properties Reddish yellow
Container ID C-009623
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C16H27BrS
Frequency of First Point 3998.34 cm⁻¹
Frequency of Last Point 339.463 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C16H27BrS/c1-2-3-4-5-6-7-8-9-10-11-12-15-13-14-18-16(15)17/h13-14H,2-12H2,1H3
InChIKey IMILVTHOOISGRW-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Molecular Weight 331.356 g/mol
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -2083
Peak Amplitude 2nd Channel 1
Peak Location 7364
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Liquid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 97%
Relative Humidity Interferometer 20 %
Resolution 4
SKU B3691-1G
SMILES c1sc(c(c1)CCCCCCCCCCCC)Br
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.308 s
Scanner Temperature 28.4 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique ATR-Neat
Zero Filling Factor 4