3,4-dihydro-7-nitro-1(2H)-naphthalenone
SpectraBase Compound ID BrfOIVOjajq
InChI InChI=1S/C10H9NO3/c12-10-3-1-2-7-4-5-8(11(13)14)6-9(7)10/h4-6H,1-3H2
InChIKey GWAQYWSNCVEJMW-UHFFFAOYSA-N
Mol Weight 191.19 g/mol
Molecular Formula C10H9NO3
Exact Mass 191.058243 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID HNT4JnB5mdN
Name 7-Nitro-1-tetralone
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number N0945
Lot Number 4MZFL-HH
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 3087
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 40353-34-2
Calibration Lamp Spectrum Correction.0
Color Properties White-pale yellow
Container ID C-009703
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C10H9NO3
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C10H9NO3/c12-10-3-1-2-7-4-5-8(11(13)14)6-9(7)10/h4-6H,1-3H2
InChIKey GWAQYWSNCVEJMW-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 191.186 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 254
Optical Filter Setting Open
Peak Amplitude 3061
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU N0945-1G
SMILES O=N(=O)c1cc2C(CCCc2cc1)=O
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 3,4-Dihydro-7-nitro-1(2H)-naphthalenone
Technique FT-Raman
Zero Filling Factor 4