For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
Indole-7-carboxylic acid
SpectraBase Compound ID 7hnwVkA18b8
InChI InChI=1S/C9H7NO2/c11-9(12)7-3-1-2-6-4-5-10-8(6)7/h1-5,10H,(H,11,12)
InChIKey IPDOBVFESNNYEE-UHFFFAOYSA-N
Mol Weight 161.16 g/mol
Molecular Formula C9H7NO2
Exact Mass 161.047678 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID GqYS1Z3FwLG
Name Indole-7-carboxylic acid
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H54931
Lot Number H16Z049
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 7751
Backward Peak Location 28687
Beam Splitter Setting Quartz
CAS Registry Number 1670-83-3
Calibration Lamp Spectrum Correction.0
Container ID C-009801
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C9H7NO2
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C9H7NO2/c11-9(12)7-3-1-2-6-4-5-10-8(6)7/h1-5,10H,(H,11,12)
InChIKey IPDOBVFESNNYEE-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 161.160 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 256
Optical Filter Setting Open
Peak Amplitude -7471
Peak Location 28693
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Liquid
Preamplifier Gain 0
Purity 97%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU H54931-1G
SMILES [nH]1c2c(C(O)=O)cccc2cc1
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 7-Indolecarboxylic acid
Technique FT-Raman
Zero Filling Factor 4