For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
2-tert-Butyl-2-[2-(4-chlorophenyl)ethyl]oxirane
SpectraBase Compound ID 5YeqdtUw4fp
InChI InChI=1S/C14H19ClO/c1-13(2,3)14(10-16-14)9-8-11-4-6-12(15)7-5-11/h4-7H,8-10H2,1-3H3
InChIKey QLCGXXYDHCTVKP-UHFFFAOYSA-N
Mol Weight 238.76 g/mol
Molecular Formula C14H19ClO
Exact Mass 238.112443 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID GZ8KHNmCrmw
Name 2-tert-Butyl-2-[2-(4-chlorophenyl)ethyl]oxirane
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number B3290
Lot Number H50DC-EG
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 16
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.27055
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1512
Backward Peak Location 7370
Beam Splitter Setting KBr
CAS Registry Number 80443-63-6
Color Properties Reddish yellow
Container ID C-010280
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C14H19ClO
Frequency of First Point 3998.31 cm⁻¹
Frequency of Last Point 339.461 cm⁻¹
High Folding Limit 15800.4
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C14H19ClO/c1-13(2,3)14(10-16-14)9-8-11-4-6-12(15)7-5-11/h4-7H,8-10H2,1-3H3
InChIKey QLCGXXYDHCTVKP-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Molecular Weight 238.758 g/mol
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1584
Peak Amplitude 2nd Channel 1
Peak Location 7366
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Liquid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity >96.0%
Relative Humidity Interferometer 0 %
Resolution 4
SKU B3290-5G
SMILES c1cc(ccc1CCC1(CO1)C(C)(C)C)Cl
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.337 s
Scanner Temperature 27.9 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique ATR-Neat
Zero Filling Factor 4