For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
[BICYCLOHEXYL]-2-ONE
SpectraBase Compound ID 3H6C4dobrg
InChI InChI=1S/C12H20O/c13-12-9-5-4-8-11(12)10-6-2-1-3-7-10/h10-11H,1-9H2
InChIKey UOBQDYFTAJKQAL-UHFFFAOYSA-N
Mol Weight 180.29 g/mol
Molecular Formula C12H20O
Exact Mass 180.151415 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID GTY2w8twMYh
Name 2-Cyclohexylcyclohexanone
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number C0612
Lot Number 5FIME-Q0
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270541
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 16
Background Scans or Time Scans
Backward Peak Amplitude -8546
Backward Peak Location 14480
Beam Splitter Setting KBr
CAS Registry Number 90-42-6
Container ID C-010404
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C12H20O
Frequency of First Point 3999.76 cm⁻¹
Frequency of Last Point 339.943 cm⁻¹
High Folding Limit 15800.4
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C12H20O/c13-12-9-5-4-8-11(12)10-6-2-1-3-7-10/h10-11H,1-9H2
InChIKey UOBQDYFTAJKQAL-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 180.291 g/mol
Non Linearity Correction 0
Number of Points 15181
Number of Sample Scans 16
Optical Filter Setting Open
Peak Amplitude -8471
Peak Amplitude 2nd Channel 1
Peak Location 14476
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Liquid
Preamplifier Gain Background 0
Purity >97.0%
Relative Humidity Interferometer 0 %
Resolution 2
SKU C0612-5G
SMILES C1C(C(CCC1)C1CCCCC1)=O
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 24.992 s
Scanner Temperature 29.8 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique Neat
Window KBr Window - 1 Side
Zero Filling Factor 8