For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
1-Bromo-3,5-dihexylbenzene
SpectraBase Compound ID 81eVqPdVmZ0
InChI InChI=1S/C18H29Br/c1-3-5-7-9-11-16-13-17(15-18(19)14-16)12-10-8-6-4-2/h13-15H,3-12H2,1-2H3
InChIKey FVTKYSBFHHVYJG-UHFFFAOYSA-N
Mol Weight 325.33 g/mol
Molecular Formula C18H29Br
Exact Mass 324.145264 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID GPmMwdjNOIP
Name 1-Bromo-3,5-dihexylbenzene
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number B4818
Lot Number SM4PJ-EG
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude -1276
Backward Peak Location 28683
Beam Splitter Setting Quartz
CAS Registry Number 1238156-36-9
Calibration Lamp Spectrum Correction.0
Color Properties Colorless-pale yellow
Container ID C-009373
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C18H29Br
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C18H29Br/c1-3-5-7-9-11-16-13-17(15-18(19)14-16)12-10-8-6-4-2/h13-15H,3-12H2,1-2H3
InChIKey FVTKYSBFHHVYJG-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 325.334 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 60
Optical Filter Setting Open
Peak Amplitude -1300
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU B4818-1G
SMILES c1c(cc(cc1Br)CCCCCC)CCCCCC
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4