For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
5-Amino-2-methylbenzonitrile
SpectraBase Compound ID FRGLvO4M3S1
InChI InChI=1S/C8H8N2/c1-6-2-3-8(10)4-7(6)5-9/h2-4H,10H2,1H3
InChIKey YDZVQWCVKXYGIU-UHFFFAOYSA-N
Mol Weight 132.17 g/mol
Molecular Formula C8H8N2
Exact Mass 132.068748 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID GB988d11IR7
Name 5-Amino-2-methylbenzonitrile
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number A2814
Lot Number O4MWI-JK
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270264
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -10608
Backward Peak Location 14479
Beam Splitter Setting KBr
CAS Registry Number 50670-64-9
Color Properties White-pale reddish yellow
Container ID C-009445
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C8H8N2
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C8H8N2/c1-6-2-3-8(10)4-7(6)5-9/h2-4H,10H2,1H3
InChIKey YDZVQWCVKXYGIU-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 132.166 g/mol
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -10563
Peak Amplitude 2nd Channel 1
Peak Location 14476
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Liquid
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 20 %
Resolution 2
SKU A2814-1G
SMILES Nc1cc(c(cc1)C)C#N
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.053 s
Scanner Temperature 26.5 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms 5-Amino-o-tolunitrile
Technique KBr0
Zero Filling Factor 8