For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
N-Acetyl-D-mannosamine monohydrate
SpectraBase Compound ID 8eO1ePS71bM
InChI InChI=1S/C8H15NO6.H2O/c1-3(11)9-5-7(13)6(12)4(2-10)15-8(5)14;/h4-8,10,12-14H,2H2,1H3,(H,9,11);1H2/t4-,5+,6-,7-,8?;/m1./s1
InChIKey VVQPUTSNIMAJPT-YTMKKKKMSA-N
Mol Weight 239.224 g/mol
Molecular Formula C8H17NO7
Exact Mass 239.100502 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID G7rXJAQuIWs
Name N-Acetyl-D-mannosamine monohydrate
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number L11167
Lot Number 10202203
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 2450
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 7772-94-3
Calibration Lamp Spectrum Correction.0
Container ID C-009833
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C8H17NO7
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C8H15NO6.H2O/c1-3(11)9-5-7(13)6(12)4(2-10)15-8(5)14;/h4-8,10,12-14H,2H2,1H3,(H,9,11);1H2/t4-,5+,6-,7-,8?;/m1./s1
InChIKey VVQPUTSNIMAJPT-YTMKKKKMSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 34
Optical Filter Setting Open
Peak Amplitude 2439
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 99%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU L11167-1G
SMILES O.OC1[C@]([C@]([C@@]([C@](O1)(CO)[H])(O)[H])(O)[H])(NC(=O)C)[H]
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms N-[2,4,5-Trihydroxy-6-(hydroxymethyl)oxan-3-yl]acetamide
Technique FT-Raman
Zero Filling Factor 4