SpectraBase Spectrum ID |
G6GxLnnem1Z |
Name |
N-[(9H-Fluoren-9-ylmethoxy)carbonyl]-L-threonine monohydrate |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
F0455 |
Lot Number |
FHM01-TAGG |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Additional Data Treatment |
1 |
Aperture Setting |
2.5 mm |
Apodization Function |
Norton-Beer, medium |
Backward Peak Amplitude |
2329 |
Backward Peak Location |
28691 |
Beam Splitter Setting |
Quartz |
CAS Registry Number |
73731-37-0 |
Calibration Lamp Spectrum |
Correction.0 |
Color Properties |
White-pale yellow |
Container ID |
C-009415 |
Copyright |
Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
15 s |
Detector Setting |
LN-Ge Diode [Internal Pos.2] |
End Frequency Limit for File |
9394.3 |
External Analog Signals |
Off |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C19H21NO6 |
Frequency of First Point |
3597.8 cm⁻¹ |
Frequency of Last Point |
-1.29183 cm⁻¹ |
High Folding Limit |
31596.8 |
High Frequency Limit |
30000 cm⁻¹ |
High Pass Filter |
1 |
InChI |
InChI=1S/C19H19NO5.H2O/c1-11(21)17(18(22)23)20-19(24)25-10-16-14-8-4-2-6-12(14)13-7-3-5-9-15(13)16;/h2-9,11,16-17,21H,10H2,1H3,(H,20,24)(H,22,23);1H2/t11-,17+;/m1./s1 |
InChIKey |
CGNQPFAECJFQNV-NRNQBQMASA-N |
Instrument Name |
Bruker MultiRAM Stand Alone FT-Raman Spectrometer |
Laser Wavenumber |
15798.4 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
5 |
Measurement Channel |
Raman Compartment |
Molecular Weight |
359.378 g/mol |
Non Linearity Correction |
0 |
Number of Points |
7466 |
Number of Sample Scans |
228 |
Optical Filter Setting |
Open |
Peak Amplitude |
2260 |
Peak Location |
28692 |
Phase Correction Mode |
power spectrum |
Phase Resolution |
1 |
Physical State |
Liquid |
Preamplifier Gain |
0 |
Purity |
98% |
Raman Background Corrected |
Yes |
Raman Corrections |
Referenced to internal light source; Scattering corrected |
Raman Laser Source |
Nd:YAG |
Raman Scattering Corrected |
Yes |
Resolution |
2 |
SKU |
F0455-1G |
SMILES |
O.OC([C@]([C@@](C)(O)[H])(NC(OCC1c2ccccc2-c2ccccc12)=O)[H])=O |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
2 |
Scan Time |
0 s |
Scanner Velocity |
5 kHz |
Signal Gain, Sample |
2 |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
5794.76 cm⁻¹ |
Synonyms |
Fmoc-L-Threonine monohydrate |
Technique |
FT-Raman |
Zero Filling Factor |
4 |