SpectraBase Spectrum ID |
FzA65yGZnGj |
Name |
6,8-Dichlorochromone-3-carbonitrile |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
C3178 |
Lot Number |
OOPQH-IA |
Accessory |
TRANS *14560FA0 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
0 |
Analog Signal 1 |
0.270331 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-11518 |
Backward Peak Location |
14480 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
72798-32-4 |
Color Properties |
White |
Container ID |
C-009648 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
0 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C10H3Cl2NO2 |
Frequency of First Point |
3999.54 cm⁻¹ |
Frequency of Last Point |
339.945 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C10H3Cl2NO2/c11-6-1-7-9(14)5(3-13)4-15-10(7)8(12)2-6/h1-2,4H |
InChIKey |
YERQUFAYRCSXEQ-UHFFFAOYSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
KBr Capsule ID |
K-04697 |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Molecular Weight |
240.045 g/mol |
Non Linearity Correction |
0 |
Number of Points |
15180 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-12042 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
14476 |
Peak Location 2nd Channel |
1 |
Pellet ID |
P-04505 |
Phase Correction Mode |
Mertz |
Phase Resolution |
4 |
Physical State |
Solid |
Preamplifier Gain Background |
0 |
Purity |
98% |
Relative Humidity Interferometer |
10 % |
Resolution |
2 |
SKU |
C3178-1G |
SMILES |
c12cc(cc(c1O\C=C/(C2=O)C#N)Cl)Cl |
Sample Capsule ID |
S-04697 |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
50.071 s |
Scanner Temperature |
28.1 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Technique |
KBr1 |
Zero Filling Factor |
8 |