For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
N-(4-Hydroxyphenyl)thiophene-2-carboxamide
SpectraBase Compound ID HMXPuS9qxiY
InChI InChI=1S/C11H9NO2S/c13-9-5-3-8(4-6-9)12-11(14)10-2-1-7-15-10/h1-7,13H,(H,12,14)
InChIKey XBRSNMYZHZKDSW-UHFFFAOYSA-N
Mol Weight 219.26 g/mol
Molecular Formula C11H9NO2S
Exact Mass 219.0354 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID FuWhSCg6MIy
Name N-(4-Hydroxyphenyl)thiophene-2-carboxamide
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H32772
Lot Number 10161149
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270522
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -10479
Backward Peak Location 14490
Beam Splitter Setting KBr
CAS Registry Number 98902-53-5
Container ID C-009772
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C11H9NO2S
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C11H9NO2S/c13-9-5-3-8(4-6-9)12-11(14)10-2-1-7-15-10/h1-7,13H,(H,12,14)
InChIKey XBRSNMYZHZKDSW-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 219.258 g/mol
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -9948
Peak Amplitude 2nd Channel 1
Peak Location 14466
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Liquid
Preamplifier Gain Background 0
Purity 97%
Relative Humidity Interferometer 0 %
Resolution 2
SKU H32772-1G
SMILES N(c1ccc(cc1)O)C(c1cccs1)=O
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.044 s
Scanner Temperature 29.4 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique KBr0
Zero Filling Factor 8