SpectraBase Spectrum ID |
Fsmr7kLznhP |
Name |
N-tert-Butyloxycarbonyl-1-tert-butyloxycarbonyl-L-tryptophan |
Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
Catalog Number |
H62542 |
Lot Number |
N21D023 |
Accessory |
DuraSample IR #145404C7 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
8 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
1 |
Analog Signal 1 |
0.270422 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Rotations |
32 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-1837 |
Backward Peak Location |
7370 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
144599-95-1 |
Color Properties |
White to off-white |
Container ID |
C-009873 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
1 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C21H28N2O6 |
Frequency of First Point |
3998.29 cm⁻¹ |
Frequency of Last Point |
339.46 cm⁻¹ |
High Folding Limit |
15800.3 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C21H28N2O6/c1-20(2,3)28-18(26)22-15(17(24)25)11-13-12-23(19(27)29-21(4,5)6)16-10-8-7-9-14(13)16/h7-10,12,15H,11H2,1-6H3,(H,22,26)(H,24,25)/t15-/m0/s1 |
InChIKey |
FATGZMFSCKUQGO-HNNXBMFYSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.3 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Measurement Channel |
Sample Compartment |
Molecular Weight |
404.463 g/mol |
Non Linearity Correction |
0 |
Number of Points |
3795 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-1896 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
7366 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
8 |
Preamplifier Gain |
3 |
Preamplifier Gain Background |
0 |
Purity |
95% |
Relative Humidity Interferometer |
20 % |
Resolution |
4 |
SKU |
H62542-1G |
SMILES |
N([C@](C(O)=O)(Cc1c[n](c2ccccc12)C(OC(C)(C)C)=O)[H])C(OC(C)(C)C)=O |
Sample Comments |
Sample ground at metal edge of ATR |
Sample Rotations |
32 |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
27.293 s |
Scanner Temperature |
28.2 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Signal Gain, Sample |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
N,N'-Di-tert-Butyloxycarbonyl-L-tryptophan |
Technique |
ATR-Neat |
Zero Filling Factor |
4 |