For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
3-Bromo-9-(p-tolyl)-9H-carbazole
SpectraBase Compound ID 8COaNLnIBLw
InChI InChI=1S/C19H14BrN/c1-13-6-9-15(10-7-13)21-18-5-3-2-4-16(18)17-12-14(20)8-11-19(17)21/h2-12H,1H3
InChIKey RODQKGBYDIAMCF-UHFFFAOYSA-N
Mol Weight 336.23 g/mol
Molecular Formula C19H14BrN
Exact Mass 335.030962 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID FoP1eWwbN1Y
Name 3-Bromo-9-(p-tolyl)-9H-carbazole
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number B5052
Lot Number 6U4FM-CT
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270473
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1804
Backward Peak Location 7372
Beam Splitter Setting KBr
CAS Registry Number 731016-44-7
Container ID C-009390
Copyright Copyright © 2018-2025 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C19H14BrN
Frequency of First Point 3998.34 cm⁻¹
Frequency of Last Point 339.463 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C19H14BrN/c1-13-6-9-15(10-7-13)21-18-5-3-2-4-16(18)17-12-14(20)8-11-19(17)21/h2-12H,1H3
InChIKey RODQKGBYDIAMCF-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Molecular Weight 336.232 g/mol
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1823
Peak Amplitude 2nd Channel 1
Peak Location 7364
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Solid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 97%
Relative Humidity Interferometer 10 %
Resolution 4
SKU B5052-1G
SMILES c12[n](c3ccc(cc3c1cccc2)Br)-c1ccc(cc1)C
Sample Comments Sample ground at metal edge of ATR
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.307 s
Scanner Temperature 28.4 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique ATR-Neat
Zero Filling Factor 4