SpectraBase Spectrum ID |
FizO9LD1bcQ |
Name |
4-tert-Butyl N-[(9H-fluoren-9-ylmethoxy)carbonyl]-D-aspartate |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
B4619 |
Lot Number |
WALDE-JA |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Additional Data Treatment |
1 |
Aperture Setting |
2.5 mm |
Apodization Function |
Norton-Beer, medium |
Backward Peak Amplitude |
1404 |
Backward Peak Location |
28691 |
Beam Splitter Setting |
Quartz |
CAS Registry Number |
112883-39-3 |
Calibration Lamp Spectrum |
Correction.0 |
Color Properties |
White |
Container ID |
C-009463 |
Copyright |
Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
15 s |
Detector Setting |
LN-Ge Diode [Internal Pos.2] |
End Frequency Limit for File |
9394.3 |
External Analog Signals |
Off |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C23H25NO6 |
Frequency of First Point |
3597.8 cm⁻¹ |
Frequency of Last Point |
-1.29183 cm⁻¹ |
High Folding Limit |
31596.8 |
High Frequency Limit |
30000 cm⁻¹ |
High Pass Filter |
1 |
InChI |
InChI=1S/C23H25NO6/c1-23(2,3)30-20(25)12-19(21(26)27)24-22(28)29-13-18-16-10-6-4-8-14(16)15-9-5-7-11-17(15)18/h4-11,18-19H,12-13H2,1-3H3,(H,24,28)(H,26,27)/t19-/m1/s1 |
InChIKey |
FODJWPHPWBKDON-LJQANCHMSA-N |
Instrument Name |
Bruker MultiRAM Stand Alone FT-Raman Spectrometer |
Laser Wavenumber |
15798.4 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
5 |
Measurement Channel |
Raman Compartment |
Molecular Weight |
411.454 g/mol |
Non Linearity Correction |
0 |
Number of Points |
7466 |
Number of Sample Scans |
152 |
Optical Filter Setting |
Open |
Peak Amplitude |
1427 |
Peak Location |
28692 |
Phase Correction Mode |
power spectrum |
Phase Resolution |
1 |
Physical State |
Solid |
Preamplifier Gain |
0 |
Purity |
98% |
Raman Background Corrected |
Yes |
Raman Corrections |
Referenced to internal light source; Scattering corrected |
Raman Laser Source |
Nd:YAG |
Raman Scattering Corrected |
Yes |
Resolution |
2 |
SKU |
B4619-1G |
SMILES |
OC([C@@](CC(OC(C)(C)C)=O)(NC(OCC1c2ccccc2-c2ccccc12)=O)[H])=O |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
2 |
Scan Time |
0 s |
Scanner Velocity |
5 kHz |
Signal Gain, Sample |
2 |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
5794.76 cm⁻¹ |
Synonyms |
Nα-Fmoc-D-aspartic acid β-tert-butyl ester |
Technique |
FT-Raman |
Zero Filling Factor |
4 |