4-chloro-2-(methylthio)-5-pyrimidinecarboxylic acid, ethyl ester
SpectraBase Compound ID 9XDiYSJlctC
InChI InChI=1S/C8H9ClN2O2S/c1-3-13-7(12)5-4-10-8(14-2)11-6(5)9/h4H,3H2,1-2H3
InChIKey SNNHLSHDDGJVDM-UHFFFAOYSA-N
Mol Weight 232.68 g/mol
Molecular Formula C8H9ClN2O2S
Exact Mass 232.007326 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID FZG2p2PICpi
Name Ethyl 4-chloro-2-(methylthio)pyrimidine-5-carboxylate
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number E0841
Lot Number 3HEBM-I0
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 16
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270548
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1410
Backward Peak Location 7370
Beam Splitter Setting KBr
CAS Registry Number 5909-24-0
Color Properties White
Container ID C-010355
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C8H9ClN2O2S
Frequency of First Point 3998.31 cm⁻¹
Frequency of Last Point 339.461 cm⁻¹
High Folding Limit 15800.4
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C8H9ClN2O2S/c1-3-13-7(12)5-4-10-8(14-2)11-6(5)9/h4H,3H2,1-2H3
InChIKey SNNHLSHDDGJVDM-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Molecular Weight 232.685 g/mol
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1458
Peak Amplitude 2nd Channel 1
Peak Location 7365
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity >97.0%
Relative Humidity Interferometer 0 %
Resolution 4
SKU E0841-5G
SMILES c1c(c(nc(n1)SC)Cl)C(OCC)=O
Sample Comments Sample ground at metal edge of ATR
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.299 s
Scanner Temperature 29.8 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms 4-Chloro-2-(methylthio)pyrimidine-5-carboxylic acid ethyl ester
Technique ATR-Neat
Zero Filling Factor 4