SpectraBase Spectrum ID |
FYWySrF2ow2 |
Name |
O-(endo-5-Norbornene-2,3-dicarboximido)-N,N,N',N'-tetramethyluronium tetrafluoroborate |
Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
Catalog Number |
H54194 |
Lot Number |
BC150502 |
Accessory |
DuraSample IR #145404C7 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
8 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
1 |
Analog Signal 1 |
0.270418 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Rotations |
32 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-1973 |
Backward Peak Location |
7369 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
125700-73-4 |
Color Properties |
White |
Container ID |
C-009786 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
1 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C14H20BF4N3O3 |
Frequency of First Point |
3998.34 cm⁻¹ |
Frequency of Last Point |
339.463 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C14H20N3O3.BF4/c1-15(2)14(16(3)4)20-17-12(18)10-8-5-6-9(7-8)11(10)13(17)19;2-1(3,4)5/h5-6,8-11H,7H2,1-4H3;/q+1;-1/t8-,9+,10-,11+; |
InChIKey |
DMTWWFCCBWWXSA-NIQYDHDSSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Measurement Channel |
Sample Compartment |
Non Linearity Correction |
0 |
Number of Points |
3795 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-1993 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
7366 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
8 |
Physical State |
Solid |
Preamplifier Gain |
3 |
Preamplifier Gain Background |
0 |
Purity |
98+% |
Relative Humidity Interferometer |
10 % |
Resolution |
4 |
SKU |
H54194-1G |
SMILES |
[C@]12([C@]3(\C=C/[C@@]([C@]2(C(N(C1=O)OC(N(C)C)=[N+](C)C)=O)[H])(C3)[H])[H])[H].F[B-](F)(F)F |
Sample Comments |
Sample ground at metal edge of ATR |
Sample Rotations |
32 |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
27.295 s |
Scanner Temperature |
28.5 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Signal Gain, Sample |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
O-(Bicyclo[2.2.1]hept-5-ene-2,3-dicarboximido)-N,N,N',N'-tetramethyluronium tetrafluoroborate; TNTU |
Technique |
ATR-Neat |
Zero Filling Factor |
4 |