SpectraBase Spectrum ID |
F9hRjWOpT4l |
Name |
Alibendol |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
A2965 |
Lot Number |
IUD7B-GK |
Accessory |
DuraSample IR #145404C7 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
8 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
1 |
Analog Signal 1 |
0.27023 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Rotations |
32 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-1820 |
Backward Peak Location |
7369 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
26750-81-2 |
Color Properties |
White- pale yellow |
Container ID |
C-009611 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
1 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C13H17NO4 |
Frequency of First Point |
3998.34 cm⁻¹ |
Frequency of Last Point |
339.463 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C13H17NO4/c1-3-4-9-7-10(13(17)14-5-6-15)12(16)11(8-9)18-2/h3,7-8,15-16H,1,4-6H2,2H3,(H,14,17) |
InChIKey |
UMJHTFHIQDEGKB-UHFFFAOYSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Measurement Channel |
Sample Compartment |
Molecular Weight |
251.282 g/mol |
Non Linearity Correction |
0 |
Number of Points |
3795 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-1841 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
7366 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
8 |
Physical State |
Solid |
Preamplifier Gain |
3 |
Preamplifier Gain Background |
0 |
Purity |
98% |
Relative Humidity Interferometer |
20 % |
Resolution |
4 |
SKU |
A2965-1G |
SMILES |
Oc1c(C(NCCO)=O)cc(cc1OC)CC=C |
Sample Comments |
Sample ground at metal edge of ATR |
Sample Rotations |
32 |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
27.297 s |
Scanner Temperature |
26.5 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Signal Gain, Sample |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
2-Hydroxy-N-(2-hydroxyethyl)-3-methoxy-5-(prop-2-en-1-yl)benzamide |
Technique |
ATR-Neat |
Zero Filling Factor |
4 |