1-Bromo-3-fluoro-2-nitrobenzene
SpectraBase Compound ID KPmysthTT17
InChI InChI=1S/C6H3BrFNO2/c7-4-2-1-3-5(8)6(4)9(10)11/h1-3H
InChIKey VFPAOFBPEYCAAZ-UHFFFAOYSA-N
Mol Weight 220.0 g/mol
Molecular Formula C6H3BrFNO2
Exact Mass 218.93312 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID F6QNmcyx5Ki
Name 1-Bromo-3-fluoro-2-nitrobenzene
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number B4842
Lot Number A2UHO-HI
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 1773
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 886762-70-5
Calibration Lamp Spectrum Correction.0
Color Properties Pale yellow
Container ID C-009715
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C6H3BrFNO2
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C6H3BrFNO2/c7-4-2-1-3-5(8)6(4)9(10)11/h1-3H
InChIKey VFPAOFBPEYCAAZ-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 219.997 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 208
Optical Filter Setting Open
Peak Amplitude 1814
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU B4842-1G
SMILES N(=O)(=O)c1c(cccc1Br)F
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman