For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
4-Bromo-2-fluorobenzenesulfonyl chloride
SpectraBase Compound ID C08yPoE0Qs8
InChI InChI=1S/C6H3BrClFO2S/c7-4-1-2-6(5(9)3-4)12(8,10)11/h1-3H
InChIKey XNYBZLRIUHNRQY-UHFFFAOYSA-N
Mol Weight 273.5 g/mol
Molecular Formula C6H3BrClFO2S
Exact Mass 271.870969 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID EyVnjPYVJIi
Name 4-Bromo-2-fluorobenzenesulfonyl chloride
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number B24352
Lot Number 10184773
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270446
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -9522
Backward Peak Location 14479
Beam Splitter Setting KBr
CAS Registry Number 216159-03-4
Container ID C-008304
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C6H3BrClFO2S
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C6H3BrClFO2S/c7-4-1-2-6(5(9)3-4)12(8,10)11/h1-3H
InChIKey XNYBZLRIUHNRQY-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 273.503 g/mol
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -9092
Peak Amplitude 2nd Channel 1
Peak Location 14477
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Solid
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 20 %
Resolution 2
SKU B24352-1G
SMILES c1c(c(cc(c1)Br)F)S(=O)(=O)Cl
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.045 s
Scanner Temperature 29.1 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Solvent Dichloromethane
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique Film
Window KBr Window
Zero Filling Factor 8