For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
5-Amino-2-methylbenzonitrile
SpectraBase Compound ID FRGLvO4M3S1
InChI InChI=1S/C8H8N2/c1-6-2-3-8(10)4-7(6)5-9/h2-4H,10H2,1H3
InChIKey YDZVQWCVKXYGIU-UHFFFAOYSA-N
Mol Weight 132.17 g/mol
Molecular Formula C8H8N2
Exact Mass 132.068748 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID EiNkKLN1gKK
Name 5-Amino-2-methylbenzonitrile
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number A2814
Lot Number O4MWI-JK
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270225
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1884
Backward Peak Location 7369
Beam Splitter Setting KBr
CAS Registry Number 50670-64-9
Color Properties White-pale reddish yellow
Container ID C-009445
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C8H8N2
Frequency of First Point 3998.34 cm⁻¹
Frequency of Last Point 339.463 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C8H8N2/c1-6-2-3-8(10)4-7(6)5-9/h2-4H,10H2,1H3
InChIKey YDZVQWCVKXYGIU-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Molecular Weight 132.166 g/mol
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1916
Peak Amplitude 2nd Channel 1
Peak Location 7366
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Liquid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 20 %
Resolution 4
SKU A2814-1G
SMILES Nc1cc(c(cc1)C)C#N
Sample Comments Sample ground at metal edge of ATR
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.297 s
Scanner Temperature 26.2 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms 5-Amino-o-tolunitrile
Technique ATR-Neat
Zero Filling Factor 4